System
Dimensions
Techincal
Flue Options

Grandee System

Wall Mounted System

Floor Standing System

Technical Information
Grandee System Wall Mounted

Grandee System Model :

SYSW 15/20

SYSW 20/24

SYSW 24/27

Nominal kW19
Heat Output Btu/h

19
65,000

23.4
80,000

29
1000,00

Nominal Btu/h
Heat Input kW

71,650
21

88,000
26

111,110
32.5

Burner

EOGB Sterling H.W.

EOGB Sterling H.W.

EOGB Sterling H.W.

Weight Empty kg

102

116

128

ibs

224.4

225

282

Weight Full kg
ibs

148
325.6

156
343

153
337

Water Litres
Content Gallons

 

45
10

30
6.5

Fuel

Kerosene
C2

Kerosene
C2

Kerosene
Class C2

Flue Type

Balanced

Balanced

Balanced

Appliance Full Load
Efficiency %

90

91

90

Exit Flue Con. mm
Diameter ins

50
2"

50
2"

63
2.5"

Exit Flue Gas C
Temp at Rated Output

200 C+
Ambient

227 C +
Ambient

235 C+
Ambient

Exit Flue Gas kg/
Mass Flow sec

.005 kg / sec

.0128 kg / sec

.0151 kg / sec

Fuel Burning kg /
Rate sec

0.48

0.646

0.795

Control Thermostat

Adjustable between 50 C - 75 C

High Limit Thermostat

Factory set 95 C

Waterside Resistance m/bar

2.5 at 20 CDiff 9.0 at 10 CDiff

23 at 10 CDff

Flow & Return
connections

2 x 22mm

System Types

Sealed

Indicator Lights

Mains - Amber

High Limit Stat-Red

Max Hearth Temp C

Below 85 C

Max Side Panel Temp C

Below 35C plus Ambient

Max Temp adjusting
Control and Safety
devices C

30 C

Max Emission Limits

Class 1

Max Operating Pressure

45p.s.i. (4.5 Bar)

Test Pressure

65p.s.i. (4.5 Ba)

Electricity Supply

220 240V Phase 150Hz amp fuse

Acousic

Specialised foam material where applicable

 

| contact | privacy | terms and conditions |


Copyright (C) Heating World Appliances Ltd all rights reserved

combi system standard external fireplace